- New
The 5702 and 5702 R laboratory centrifuges are compact, low-speed benchtop centrifuges designed for general laboratory research, cell culture applications and routine sample preparation. Their space-saving design and intuitive operation make them suitable for research laboratories, biotechnology facilities, universities, pharmaceutical research laboratories and life science laboratories processing low to medium sample volumes.
These 5702 / 5702 R centrifuges without rotor allow laboratories to select a compatible rotor separately according to their specific sample requirements. The rotational speed ranges from 100 to 4,400 rpm, with the maximum operating speed depending on the installed rotor.
Both models feature a maintenance-free motor, rotary control knobs, digital display, motorized lid locking system and stainless steel rotor chamber. An optimized airflow system directs air towards the rear of the instrument to assist sample cooling during operation.
The 5702 standard centrifuge is designed for applications that do not require active refrigeration and features automatic lid opening. The 5702 R refrigerated centrifuge offers adjustable temperature settings from -9 °C to +40 °C, standby cooling, FastTemp functionality and two programmable memory buttons.
Short braking times help improve laboratory workflow efficiency, while the compact footprint allows convenient installation on laboratory benches where space is limited.
The 5702 and 5702 R professional laboratory centrifuges operate on a 230 V, 50/60 Hz power supply. Both are General Lab products intended for research applications and are supplied without a rotor, which must be selected separately.
The 5702 and 5702 R benchtop centrifuges are low-speed laboratory instruments designed for sample separation, cell culture workflows and general research applications. Their compact construction makes them suitable for laboratories requiring efficient centrifugation equipment with minimal bench space requirements.
The 5702 low-speed centrifuge is designed for routine laboratory applications that do not require active temperature control. Its intuitive controls and compact construction make it suitable for research laboratories performing regular sample preparation and cell culture procedures.
Features include a maintenance-free motor, motorized lid locking, automatic lid opening and a stainless steel rotor chamber.
The 5702 R refrigerated centrifuge incorporates an adjustable temperature control system with a setting range from -9 °C to +40 °C. This allows researchers to select operating temperatures according to their laboratory protocols and sample requirements.
The refrigerated model also features standby cooling and the FastTemp function, designed to facilitate temperature preparation before centrifugation.
The 5702 R centrifuge includes two program buttons for storing the parameters of two standard centrifugation procedures. This feature is useful for laboratories performing repetitive workflows with predefined operating conditions.
The refrigerated version also offers adjustable acceleration and braking rates, providing additional control over the beginning and end of each centrifugation cycle.
Both 5702 and 5702 R centrifuges are supplied without a rotor. A compatible rotor must be selected separately according to the required sample containers and laboratory applications.
Rotor selection should consider tube format, sample capacity, maximum permitted speed and relative centrifugal force (RCF).
The stated maximum speed of 4,400 rpm may not be available with every compatible rotor. The operating limits specified for the selected rotor and accessories must always be respected.
The 5702 / 5702 R low-speed centrifuges are particularly suitable for cell culture applications and sample preparation in laboratories handling low to medium sample volumes.
They can be used in biological, biotechnology and pharmaceutical research applications, provided that the samples, containers and operating parameters are compatible with the centrifuge configuration.
The main difference between the 5702 centrifuge and the 5702 R refrigerated centrifuge is the availability of active temperature control and additional operating functions.
The standard 5702 is a compact, low-speed benchtop centrifuge intended for laboratory procedures that do not require active refrigeration. It features a maintenance-free motor, rotary controls, a digital display, motorized lid locking and automatic lid opening.
The 5702 R incorporates a refrigeration system with an adjustable temperature setting range from -9 °C to +40 °C. It also provides FastTemp functionality, standby cooling, two programmable memory buttons and adjustable acceleration and braking rates.
Both centrifuges have a stated speed range of 100 to 4,400 rpm. The maximum operating speed depends on the rotor installed.
The standard 5702 may be suitable for routine centrifugation protocols that do not require refrigeration. The 5702 R is intended for applications where temperature settings and additional control over centrifugation parameters are important.
The choice should be based on the laboratory protocol, sample characteristics and required operating conditions.
The 5702 and 5702 R laboratory centrifuges offered in this configuration are supplied without a rotor. A compatible rotor must be purchased separately before the instrument can be used for centrifugation.
The rotor is an essential component that holds sample containers during operation. Its design determines the number and type of tubes that can be processed, as well as the permitted operating speed and relative centrifugal force.
When selecting a rotor, laboratories should consider the centrifuge model, sample tube dimensions, required capacity and compatibility with any necessary adapters.
It is also important to verify the maximum permitted speed and RCF of the rotor and accessories. The maximum speed stated for the centrifuge should not automatically be assumed to apply to every rotor configuration.
Purchasing the centrifuge without a rotor allows laboratories to select a configuration suited to their specific applications.
Before ordering, users should identify the required sample containers, number of samples per cycle and operating parameters specified in their laboratory protocols.
The 5702 and 5702 R low-speed centrifuges have a stated rotational speed range of 100 to 4,400 revolutions per minute (rpm).
The maximum usable speed depends on the rotor installed. Each compatible rotor has its own operating limitations, which must be respected during centrifugation.
It is important to distinguish between rotational speed, expressed in rpm, and relative centrifugal force, commonly expressed as RCF or multiples of gravitational acceleration.
RCF depends on both rotational speed and the effective radius of the rotor. Consequently, different rotors operating at the same rpm can produce different centrifugal forces.
For cell culture and biological research protocols, the required centrifugal force is often more relevant than rotational speed alone.
Laboratory personnel should therefore verify the rotor specifications and use the operating parameters recommended for the particular application.
The limits of the rotor, adapters and sample containers must always be observed.
The 5702 R refrigerated centrifuge provides adjustable temperature settings from -9 °C to +40 °C, allowing laboratories to select thermal operating conditions according to their centrifugation protocols.
Temperature control can be important when processing biological samples or performing research procedures where temperature variations may affect sample characteristics.
During centrifugation, operating conditions can influence sample temperature. A refrigerated centrifuge provides a means of managing the thermal environment during the process.
The 5702 R also includes standby cooling, allowing the refrigeration system to operate during waiting periods according to the instrument's operating settings.
The FastTemp function is designed to facilitate preparation of the centrifuge at the selected temperature.
The available temperature setting range does not mean that every sample will necessarily reach the selected temperature under all ambient conditions, rotor configurations or loading conditions.
Laboratories should evaluate their temperature requirements and consult the instrument's performance specifications before selecting the refrigerated version.
The 5702 and 5702 R laboratory centrifuges are particularly suitable for cell culture applications and sample preparation in research laboratories handling low to medium sample volumes.
Low-speed centrifugation is commonly used in biological research procedures involving the separation of suspended components or the collection of cellular material.
Suitability for a particular application depends on the laboratory protocol, sample characteristics, rotor configuration and sample containers.
The standard 5702 is designed for procedures that do not require active refrigeration, while the 5702 R offers adjustable temperature control and additional settings for acceleration and braking.
These functions may be useful when a research protocol requires defined operating conditions or more precise control over the centrifugation cycle.
Users should verify the required RCF, container compatibility and applicable biological safety procedures before processing samples.
Both centrifuges are classified as General Lab products intended for research applications and should not automatically be considered diagnostic or clinical devices.
The 5702 R refrigerated laboratory centrifuge includes additional functions designed to simplify repetitive centrifugation procedures and provide greater control over operating conditions.
Two program buttons allow users to store the parameters of two standard centrifugation processes. This is useful in laboratories that regularly perform procedures requiring the same settings.
Stored programs reduce the need to manually re-enter operating parameters before every cycle and can support more consistent workflow management.
The FastTemp function helps prepare the centrifuge at the selected temperature, while standby cooling supports temperature management between centrifugation cycles.
Another feature of the 5702 R is the ability to adjust acceleration and braking rates, allowing laboratories to control how the centrifuge reaches operating speed and returns to a stop.
These functions should always be used in accordance with the manufacturer's instructions and the requirements of the laboratory protocol.
For research laboratories performing repetitive procedures or requiring temperature control, the 5702 R provides additional functionality compared with the standard 5702 model.
Choosing between the 5702 laboratory centrifuge and the 5702 R refrigerated centrifuge requires an assessment of sample characteristics, laboratory protocols and temperature control requirements.
The standard 5702 is designed for low-speed centrifugation applications that do not require active refrigeration. It offers a compact footprint, intuitive controls, a maintenance-free motor and automatic lid opening.
The 5702 R adds temperature control from -9 °C to +40 °C, two programmable memory buttons, FastTemp functionality, standby cooling and adjustable acceleration and braking rates.
Both models offer a stated rotational speed range of 100 to 4,400 rpm and are intended for General Lab research applications.
Rotor selection is another essential consideration. Since the centrifuges are supplied without a rotor, laboratories must select a compatible rotor based on tube format, sample capacity and required centrifugal force.
The refrigerated model may be preferable for protocols involving temperature-sensitive samples or repetitive procedures requiring predefined operating conditions.
The final selection should reflect the laboratory's actual research requirements, operating procedures and complete equipment configuration.
Portable OXIMETER Set in case with sensor
Extractable agitator stirrer for tanks up to 350-700-2000 Hl
Air-cooled liquid chiller - evaporator water outlet (down to -10 °C) 232 – 1334 kW
Aphrometer for full bottles without cap
Vacuum filling machine 4 spouts 500 l/h
Environmental Ozone Generator up to 500 m3 - OXYGEN CONCENTRATOR 3 Lt
Stainless steel electric pump with flexible impeller 6 - 600 litres / minute
Filter system Housing 3 bells 1 cartridge
Ozone generator for small/medium enclosed spaces - 80 mc max
Portable Ozone Generator for sanitizing environments (150 m2)
Air cooled liquid chiller - Super low noise acoustic configuration 232 - 1334 kW